UDC3200 Universal Digital Controller

UDC3200 Universal Digital Controller

3000 INR/Unit

Product Details:

  • Input 2 Universal Analog Inputs, 2 Digital Inputs
  • Output • Current Outputs (4-20 or 0-20 ma) • Electromechanical Relays (5 amps) • Solid State Relays (1 amp) • Dual Electromechanical Relays (2 amps) • Open Collector Outputs
  • Power Supply 11 to 42 V DC
  • Product Type PID Controller
  • Application • Metals, Glass, Ceramics, Plastics • Food and Beverage • Furnaces and Ovens • Painting and Coating
  • Rated Voltage 24-240VAC Volt (V)
  • Supply Voltage 24-240VAC Volt (v)
  • Click to View more
X

UDC3200 Universal Digital Controller Price And Quantity

  • 3000 INR/Unit
  • 3000.00 - 7000.00 INR/Unit
  • 1 Unit

UDC3200 Universal Digital Controller Product Specifications

  • 1 Year
  • 24-240VAC Volt (V)
  • PID Controller
  • 2 Universal Analog Inputs, 2 Digital Inputs
  • • Infrared PC and Pocket PC Configuration • NEMA 4X, IP65 Front Face Protection • Accutune III • Ethernet and Modbus Communications
  • Black
  • • Metals, Glass, Ceramics, Plastics • Food and Beverage • Furnaces and Ovens • Painting and Coating
  • 1.3 Kilograms (kg)
  • • Current Outputs (4-20 or 0-20 ma) • Electromechanical Relays (5 amps) • Solid State Relays (1 amp) • Dual Electromechanical Relays (2 amps) • Open Collector Outputs
  • 11 to 42 V DC
  • 24-240VAC Volt (v)

UDC3200 Universal Digital Controller Trade Information

  • 10 Unit Per Day
  • 1 Week
  • Contact us for information regarding our sample policy
  • As per Standard
  • All India
  • All Standard Certifications

Product Description

Product Details :

Brand

Honeywell

Model

UDC3200

Power Consumption

20 VA maximum (90 to 264 Vac)

Input Impedance

10 megohms

Maximum Lead Wire Resistance

10 ohms/leg

Accuracy

0.20%

Frequency

50/60 Hz

Digital Inputs

2

Size

1/4 DIN

Maximum Sink Current

20 mA

Overload Protection

100 mA

Temperature Stability

0.01% F.S./ deg C

Load Resistance

0 to 1000 ohms

Voltage

120 Vac or 240 Vac or 30 Vdc

Current

5 amps

Features :

 

  • 2 Universal Analog Inputs
  • Fast scanning rate (166ms)
  • Up to 5 Analog Output Types
  • Math Functions
  • Ethernet and Modbus communication
  • Infrared PC & Pocket PC configuration
  • NEMA4X and IP66 front face protection
  • Multilanguage prompts
  • Jumper free configuration
  • Easily Field Upgradable
  • Bright, dual displays with multi-language prompts (in English, French, German,
  • Spanish, or Italian) make the operator interface easy to read, understand, and operate
  • Simple keystrokes let you set operating parameters that meet your process control needs

 

Math Functions :

 

  • Algorithm-A pre-configured algorithm is available for easy implementation.
  • This includes the capability of using a Ratio and Bias with any input.
  • You can select from the following menu: Feedforward Summer-Uses either input, followed by a Ratio/Bias calculation, summed directly with the computed PID output value to provide a resultant output to the final control element (standard feature).
  • Weighted Average Computes the weighted average of a PV or SP for the control algorithm from two inputs (standard feature)
  • Feed forward Multiplier-Uses any input, multiplied by the calculated PID output to provide a resultant output which is sent to the final control element (standard feature).
  • Summer/Subtractor-Will add or subtract inputs with the result used as the derived PV
  • Multiplier/Divider-Uses the analog inputs to calculate a derived PV
  • Available with or without Square Root
  • Input High/Low Select-Specifies the PV input as the higher or lower of the two inputs

 

Digital Inputs:

 

 

  • Two isolated digital inputs are provided for remote dry contact closure to select one of the following actions: Manual control mode
  • Local setpoint 1
  • Local setpoint 2
  • Local setpoint 3
  • Direct controller action
  • Hold SP Ramp/Program
  • Select PID set 2
  • PV = Input 2
  • ReRun - SP Ramp/Program
  • Run - SP Ramp/Program
  • External program reset
  • Disable PID integral action
  • Manual mode, failsafe output
  • Disable keyboard
  • Output 1 = Fixed value
  • Start Timer
  • Auto/Manual Station
  • Initiate Tuning
  • Initiate PV Hot Start
  • Output 1 tracks Input 2
  • To Remote Setpoint
  • PID reset feedback via Input 2
  • Purge
  • Low Fire
  • To Latching Manual Mode.
  • Also, the digital inputs can allow one of the following selections to be combined with one of the above selections: Select PID set 2
  • Direct controller action
  • Local setpoint 2 or Local setpoint 1
  • Disable Accutune
  • To Run - SP Ramp/Program
  • The 2nd Current Output and the 2nd
  • Digital Input are mutually exclusive
  • Selection is made via a keyboard entry

Other Products in 'Honeywell Digital Controller & Indicator' category



Get in touch with us
RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com